Fog-cooled Heat Rejection for the Data Center Era

Exploring a co-development partnership with cooling-equipment OEMs

Zero Water Consumption

Efficiency — COP 8

Sustainable Technology

COOLING REINVENTED

The Future of High-Density Thermal Management

Unprecedented energy efficiency for mission-critical infrastructure.

WHY INCUMBENTS ARE STUCK

Two constraints: power and water

Global data-center power demand is climbing steeply, and cooling is a large share of it. Evaporative cooling is efficient but water-hungry; air cooling is dry but power-hungry. No legacy condenser class escapes the trade-off.

Water use
200–250M gal/year

Water a single 50 MW evaporative-cooled data center can consume.

Projected Demand

Projected rise in global data-center cooling-water use as AI capacity comes online.

+870%
MANDATE

Microsoft, Google, AWS and Meta pledges — Microsoft now deploying zero-water cooling.

Water positive by 2030

THE WHITE SPACE

Three condenser classes today — none solves both

AIR-COOLED

COP 3.0–3.5 — Limited by dry-bulb ambient

Reliable and water-free, but energy intensive during peak summer loads.

WATER-COOLED

COP 5.0–6.0 — High efficiency, high consumption

Excellent thermal performance, but consumes millions of gallons of water annually.

EVAPORATIVE

COP 4.0–5.0 — Hybrid trade-off complexity

Attempts to balance water and power but fails to excel at either in density.

Infrastructure planners have long been forced to choose between wasting precious water or consuming excessive power. In high-density AI environments, neither is a viable path forward.

Foggy Labs bridges this gap: reaching COP 8 without consuming a single drop of water.

A fourth class of condenser

Foggy: fog-cooled heat rejection

Patented technology that pairs the latent-heat efficiency of water with full moisture recovery — air-cooled simplicity, water-cooled performance, zero net water loss.

1 · Atomize

Water becomes fog Water is turned into fog — and is 100% recovered downstream.

Absorb latent heat

Latent-energy transfer Fog pulls heat via latent energy — far more efficient than sensible air cooling.

Recover & recycle

Closed loop A heat exchanger condenses the vapour back to liquid in a closed loop.

COP 8.0

Efficiency Rating

Zero

Water Consumption

0.44kW/TR

POWER DRAW

No tower

cooling tower required

U.S. patent granted · India patent granted · independently audited working prototype.

HEAD-TO-HEAD

The Foggy Advantage

Wide landscape comparison table graphic with three columns labeled Air-Cooled, Water-Cooled, and Foggy
Water consumption — 50 MW site

Cooling-tower / evaporative systems · million gallons per year (lower is better)

SPX

207M

BAC

201M

EVAPCO

203M

Hamon

209M

JCI

199M

Foggy

0

Foggy vs. the competition

Across both classes the major brands cluster together — Foggy is the outlier: zero water and the lowest PUE. Illustrative comparison for discussion; per-brand figures are representative.

BENCHMARKED AGAINST THE FIELD
Power efficiency (PUE)

Air-cooled systems · lower is better

Vertiv

1.47

STULZ

1.46

Daikin

1.45

Rittal

1.45

Modine

1.44

Foggy

1.20

FITS YOUR PLATFORMS

The integration path into existing OEMs

Foggy connects into the standard chiller / condenser architecture — replacing the heat-rejection stage, not the whole plant.

REPLACE THE COOLING TOWER

For water-cooled & evaporative systems

Eliminates the primary source of water consumption. Fog + air condenses the chiller’s hot refrigerant; moisture is recovered via a secondary exchanger. Zero net water — water-cooled performance kept.

DROP-IN STAGE

Keep the rest of the plant

The chiller, distribution and controls stay; Foggy swaps in at the heat-rejection stage, minimizing redesign and re-certification effort for your platform.

WHY PARTNER WITH FOGGY

What this unlocks for your business

Category-defining SKU

A premium heat-rejection product no competitor can match on efficiency-per-gallon.

Win water-constrained deals

Lets customers meet water-positive 2030 mandates without sacrificing efficiency.

Premium margins

2× efficiency and zero water justify premium pricing over commodity condensers.

Defensible IP moat

US and India patents granted — co-exclusive licensing keeps the advantage yours.

Expand your TAM

Addresses the surge of new AI data-center builds coming online.

De-risked engineering

A working, independently audited prototype and a 50-year HVAC R&D partner.

THE CUSTOMER BUSINESS CASE

What your customers gain — a 50 MW data center

Annual (per 50 MW site)

Power Usage Effectiveness

Power used for cooling

Cooling power cost @ $0.12/kWh

Water consumed

Water cost @ $0.01/gal

Total cooling cost

Annual savings with Foggy
Air

1.44

17 MW

$18M

0 gal

$0

$18M

$12M

Water

1.25

11 MW

$12M

200M gal

$2M

$14M

$8M

Foggy
1.20

6 MW

$6M

0 gal

$0

$6M

-

Illustrative model.

LOWER OPEX

$8M+ / yr

vs. water-cooled, at a 50 MW site.

WATER SAVED

200M+ gal

Every year, every site.

MARGIN UPLIFT

+10% pts

EBITDA-margin uplift potential.

DE-RISKED

Validation, audit and intellectual property

WORKING PROTOTYPE

Built & run continuously

A 2-ton fog-cooled unit was built and run continuously in 2021.

INDEPENDENTLY AUDITED

COP 8.0 verified

Eco Energy Solution (accredited energy auditor) verified an overall COP of 8.0 and ~0.437 kW/TR SPC.

PATENT PROTECTED

USA & India granted

Patents granted in the USA and India; licensing terms negotiable.

PUBLISHED

Peer-visible

Featured as a "game-changing innovation" in Cooling India (Feb 2023).

For an OEM partner, the core technical risk is already mitigated: a built, measured, third-party-verified unit and granted IP. Co-development focuses on scale and platform fit, not feasibility.

YOUR DEVELOPMENT PARTNER

Panasia Engineers — 50+ years of HVAC innovation

Mumbai-based HVAC R&D and manufacturing powerhouse

50+ years experience in extreme-climate thermal management

OEM supplier to marquee industrial and commercial names

Dedicated R&D facility with ready manufacturing capacity

Independently audited performance and verified COP 8.0

THE INVENTOR

Surendra Shah

The visionary thermal engineer behind Foggy's recovery cycle patents and 50 years of HVAC architectural success.

THE BUILDER

Udit Shah

Driving manufacturing and execution excellence, ensuring every Foggy unit meets mission-critical reliability standards.

THE NEXT GENERATION

Ronak & Neel Shah

Leading the global data center expansion and OEM partnership bridge for the next generation of cooling needs.

PROPOSED CO-DEVELOPMENT PATHWAY

A staged path from evaluation to commercial integration

1

Technical evaluation

Validate Foggy against your platform specs and target duty points.

2

Co-engineer a prototype

Jointly develop a 25/50-ton unit built to your manufacturing and integration requirements.

3

Pilot deployment

Field-trial at a reference data center, capture performance, reliability and TCO data.

4

Commercial agreement

Co-exclusive licensing or integration — bring the product to market under your brand & channel.

FOGGY LABS BRINGS

Patented technology · audited prototype · 50 yrs of HVAC engineering & I.P.

OEM PARTNER BRINGS

Manufacturing scale · channel & customer access · platform integration.

Inquire for co-development

Ready to deploy COP 8 systems? Tell us about your infrastructure needs.